Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac and 6000.0 dc single location

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant and salt spray proof and fungus resistant

  • Spec/Std Controlling Data

  • Reset Method

    automatic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct and 50.000 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    575.0 dc single location

  • Definitive Government Spec/Std Reference

    aa55571/08-002

  • Iii End Item Identification

    m109 howitzer

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Non-Definitive Government Spec/Std Reference

    aa55571/08

  • Mounting Surface To Terminal End Distance

    2.220 inches nominal

  • Terminal Type And Quantity

    2 threaded stud

  • Criticality Code Justification

    feat

  • Iii Fragility Factor

    moderately rugged

  • Body Style

    single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    1.485 inches minimum and 1.515 inches maximum

  • Body Width

    2.120 inches nominal

  • Manufacturers Code

    58536

  • Overall Length

    4.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.500 inches nominal

  • Case Material

    plastic

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    200.0 amperes dc single location

  • Iii Storage Type

    general purpose warehouse

  • Pole Quantity

    1

  • Special Features

    weapon coded f

  • Trip Release Method

    thermal single location

  • Unthreaded Mounting Hole Diameter

    0.218 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...