7276-101-5

Circuit Breakers

CIRCUIT BREAKER

7276-101-5

5925-00-841-0679

5925 - Circuit Breakers

Bunting Bearings Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.750 inches nominal

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Body Length

    0.850 inches maximum

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.625 inches nominal

  • Body Height

    2.765 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.750 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct all locations and 35.000 maximum at 200 pct all locations

  • Thread Series Designator

    unef and unc

  • Manual Actuator Type And Quantity

    1 push-pull

  • Bushing Length

    0.281 inches nominal

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Width

    2.000 inches maximum

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Thread Quantity Per Inch

    32 and 32

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.810 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing and 4 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Nominal Thread Size

    0.375 inches and 0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac all locations

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...