S456D988G07

Circuit Breakers

CIRCUIT BREAKER

S456D988G07

5925-00-841-6817

5925 - Circuit Breakers

Westinghouse Electric Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Body Width

    5.500 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    170.000 minimum at 200 pct all locations and 460.000 maximum at 200 pct all locations

  • Body Style

    multipole-single actuator type

  • Terminal Type And Quantity

    4 compression

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Center To Center Distance Between Terminals Parallel To Width

    1.719 inches nominal

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations and 10000.0 dc all locations

  • Case Material

    plastic

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.719 inches nominal

  • Pole Quantity

    2

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    10.125 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    8.875 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    175.0 amperes ac all locations and 175.0 amperes dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.437 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Height

    4.062 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...