Technical Characteristics

  • Mounting Facility Type And Quantity

    4 slot

  • Reset Method

    manual

  • Body Length

    6.310 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.187 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.880 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal single location

  • Trip Release Method

    thermal-magnetic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Boss Height

    0.125 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Style

    single pole type

  • Mounting Slot Width

    0.370 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac single location and 125.0 dc single location

  • Body Height

    3.188 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Body Width

    1.375 inches nominal

  • Pole Quantity

    1

  • Frequency In Hertz

    60.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    120.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    5.250 inches nominal

  • Terminal Type And Quantity

    2 compression

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac single location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...