FC402-2
Relays and Solenoids
RELAY,ELECTROMAGNETIC
FC402-2
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.187 inches nominal single mounting facility
-
Purpose For Which Designed
general
-
Coil Quantity
1
-
Overall Height
2.218 inches maximum
-
Thread Series Designator
unc single mounting facility
-
Specification/Standard Data
96906-ms25273 government standard
-
Time Delay
0.05 seconds maximum fixed release time
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.687 inches nominal single mounting facility
-
Time Delay
0.025 seconds maximum fixed operate time
-
Duty Type
continuous
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
Case Material
metal
-
Frequency In Hertz
400.0 nominal
-
Thread Direction
right-hand single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac lamp load and 2.0 amperes dc lamp load
-
Terminal Type And Quantity
8 wire hook all functions
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Overall Length
1.531 inches maximum
-
Cubic Measure
3.735 cubic inches
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performance
-
Fragility Factor
moderately rugged
-
Nominal Thread Size
0.138 inches single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac motor load and 4.0 amperes dc motor load
-
Overall Width
1.100 inches maximum
-
Mounting Facility Pattern
rectangular single mounting facility
-
Storage Type
general purpose warehouse
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
-
Environmental Protection
hermetic
-
Mounting Facility Type And Quantity
4 threaded stud single mounting facility
-
Arc Quenching Method
air
-
Thread Quantity Per Inch
32 single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
6.0 amperes ac inductive load and 6.0 amperes dc inductive load
-
Winding Quantity
1
-
Thread Class
2a single mounting facility