SM3-5AMP120VAC400CYTDC58

Circuit Breakers

CIRCUIT BREAKER

SM3-5AMP120VAC400CYTDC58

5925-00-845-6609

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Thread Series Designator

    unef

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Body Width

    0.625 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Body Length

    1.500 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Pole Quantity

    1

  • Bushing Length

    0.375 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Nominal Thread Size

    0.375 inches

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Unpackaged Unit Weight

    2.100 ounces

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Special Handling Feature

    magnetic

  • Terminal Type And Quantity

    2 wire hook

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.750 minimum at 125 pct single location and 3.000 maximum at 125 pct single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...