70-133-22MG6

Circuit Breakers

CIRCUIT BREAKER

70-133-22MG6

5925-00-850-1447

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Thread Series Designator

    unc

  • Mounting Surface To Terminal End Distance

    2.595 inches minimum and 2.625 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Test Data Document

    05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Inclosure Protection Type For Which Designed

    moisture resistant and vibration resistant and shock resistant and salt spray proof

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.797 inches minimum and 1.827 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct single location and 10.000 maximum at 200 pct single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Unpackaged Unit Weight

    0.312 pounds

  • Trip Release Characteristic

    time delay single location

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...