MIL-C-5809

Circuit Breakers

CIRCUIT BREAKER

MIL-C-5809

5925-00-851-2849

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Center To Center Distance Between Terminals Parallel To Width

    1.486 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Body Length

    2.250 inches maximum

  • Terminal Type And Quantity

    6 tab w/screw

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations and 28.0 dc all locations

  • Trip Release Method

    thermal all locations

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Body Width

    2.203 inches maximum

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Body Height

    2.125 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.812 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations and 50.0 amperes dc all locations

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    explosion resistant and moisture resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Case Material

    metal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1.500 ac all locations and 2.500 dc all locations

  • Body Style

    multipole-single actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.486 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Specification/Standard Data

    96906-ms21984 government standard

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    1.187 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...