APL1-532-330
Circuit Breakers
CIRCUIT BREAKER
APL1-532-330
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Method
magnetic
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Inclosure Protection Type For Which Designed
vibration resistant and shock resistant and humidity resistant and sand resistant and dustproof and explosion proof and moisture resistant and fungus resistant and salt spray proof
-
Test Data Document
13499-260-4007 drawing
-
Terminal Type And Quantity
2 threaded stud
-
Body Length
2.530 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
-
Boss Height
0.155 inches nominal
-
Mounting Surface To Terminal End Distance
2.630 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Special Handling Feature
magnetic
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac
-
Circuit Protection Type
overcurrent
-
Thread Pitch Diameters
p0.1177/p0.1214 inches
-
Body Width
0.760 inches nominal
-
Fragility Factor
moderately rugged
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
2 threaded hole
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 8.000 maximum at 200 pct
-
Frequency In Hertz
60.0
-
Unpackaged Unit Weight
0.312 pounds
-
Thread Series Designator
unc