JN14-1968A

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

JN14-1968A

5915-00-853-3962

5915 - Filters and Networks

Sprague Electric Co

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Rating And Type Per Function

    130.0 volts ac 2nd radio interference 2nd function

  • Overall Length

    4.000 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Operating Current Rating Per Function In Amps

    0.2 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Unthreaded Mounting Hole Diameter

    0.375 inches nominal

  • Operating Current Rating Per Function In Amps

    0.5 1st radio interference

  • Operating Current Rating Per Function In Amps

    0.2 6th radio interference

  • Operating Voltage Rating And Type Per Function

    130.0 volts ac 1st radio interference 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Functional Terminal Type And Quantity

    5 tab, solder lug ground 3rd function

  • Inclosure Type

    hermetically sealed

  • Special Features

    27 functions; 2.500 in. overall width

  • Operating Current Rating Per Function In Amps

    0.5 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Test Data Document

    76301-b46n0088-1 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.500 inches nominal

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Body Length

    4.000 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    0.3 3rd radio interference

  • Operating Current Rating Per Function In Amps

    0.3 4th radio interference

  • Operating Voltage Rating And Type Per Function

    30.0 volts dc 5th radio interference 5th function

  • Operating Voltage Rating And Type Per Function

    30.0 volts dc 6th radio interference 6th function

  • Unpackaged Unit Weight

    1.400 pounds

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Input Terminal Manufacturer Code

    96906

  • Input Terminal Identification

    ms3114h-20-41p

  • Body Height

    2.625 inches nominal

  • Operating Voltage Rating And Type Per Function

    30.0 volts ac 3rd radio interference 3rd function

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Body Width

    1.370 inches nominal

  • Operating Voltage Rating And Type Per Function

    30.0 volts ac 4th radio interference 4th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • ~1

    data on certain environmental and performance

  • Maximum Temp Rise

    25.0 deg celsius

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Functional Terminal Type And Quantity

    27 tab, solder lug output 2nd function

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.000 inches nominal

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Body Material

    metal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...