1453-36

Circuit Breakers

CIRCUIT BREAKER

1453-36

5925-00-856-8103

5925 - Circuit Breakers

White Consolidated Industries Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    6 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant

  • Manual Actuator Type And Quantity

    3 toggle

  • Frequency In Hertz

    400.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.000 minimum at 150 pct all locations and 500.000 maximum at 150 pct all locations

  • Boss Height

    0.140 inches nominal

  • Body Length

    2.500 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Body Width

    2.250 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Unpackaged Unit Weight

    14.000 ounces

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    26.0 amperes ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...