X206

Coils and Transformers

TRANSFORMER,POWER

X206

5950-00-856-8217

5950 - Coils and Transformers

Dynasciences Corp Instrument

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    4.500 inches nominal

  • Mounting Slot Width

    0.250 inches nominal

  • Frequency Rating

    50.0 hertz minimum and 60.0 hertz maximum

  • Input-Output Phase Relationship

    single phase to single phase

  • Winding Shielding Method

    internal shield grounded to inclosure and core

  • Body Width

    4.562 inches nominal

  • Inclosure Type

    partially inclosed,double shell

  • Mounting Facility Quantity

    4

  • Winding Operating Voltage

    8.50 ac volts nominal and 21.00 ac volts nominal and 29.00 ac volts nominal and 42.00 ac volts nominal

  • Reliability Indicator

    not established

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    3.500 inches nominal

  • Body Length

    5.500 inches nominal

  • Body Height

    5.312 inches nominal

  • Mounting Method

    flange and slot

  • Winding Function And Quantity

    1 primary and 1 secondary

  • Winding Tap Location

    multiple taps w/o center tap

  • Winding Operating Current

    9.0 amperes ac maximum

  • Winding Operating Voltage

    115.00 ac volts nominal

  • Terminal Type And Quantity

    7 wire lead

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...