86299-1

Circuit Breakers

CIRCUIT BREAKER

86299-1

5925-00-856-9188

5925 - Circuit Breakers

Yosemite Investment Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    9b multipole-single actuator type

  • Body Length

    5.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.984 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.063 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.218 inches nominal

  • Pole Quantity

    3

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    relay trip first location

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal third location

  • Nominal Thread Size

    0.164 inches

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Frequency In Hertz

    60.0

  • Body Width

    3.000 inches nominal

  • Body Height

    2.687 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    4.359 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.984 inches nominal

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    relay trip second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct and 120.000 maximum at 200 pct all locations

  • Unpackaged Unit Weight

    1.813 pounds

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    10 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...