052-000830
Coils and Transformers
TRANSFORMER,POWER
052-000830
Northrop Grumman Systems Corporation
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
750.0 milliamperes dc nominal single component single secondary
-
Winding Operating Voltage
208.00 ac volts nominal single component single primary
-
Terminal Type And Quantity
17 tab, solder lug
-
Unpackaged Unit Weight (Non-Core)
4.750 pounds
-
Reliability Indicator
not established
-
Overall Length
5.438 inches maximum
-
Overall Height
2.688 inches maximum
-
Overall Width
3.750 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.625 inches nominal single mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
4.125 inches nominal single mounting facility single center group
-
Mounting Facility Quantity
4 single group
-
Transformer Winding Connection Type
wye-wye
-
Mounting Hole Diameter
0.188 inches nominal single group
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
flange single group and unthreaded hole single group
-
Winding Operating Voltage
1.75 ac kilovolts nominal single component single secondary
-
Features Provided
w/rectifier
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Input-Output Phase Relationship
three phase to three phase single component