JA2S-A3-EB01DA-W-20-250AC-2

Circuit Breakers

CIRCUIT BREAKER

JA2S-A3-EB01DA-W-20-250AC-2

5925-00-863-4232

5925 - Circuit Breakers

Heinemann Electric Canada Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.745 inches minimum and 0.755 inches maximum

  • External Actuator Linkage Arrangement

    one and two linked

  • Manual Actuator Type And Quantity

    2 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Terminal Type And Quantity

    4 tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.745 inches minimum and 0.755 inches maximum

  • Body Width

    1.468 inches minimum and 1.532 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    1.835 inches minimum and 1.845 inches maximum

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Pole Quantity

    2

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...