2315741P18
Circuit Breakers
CIRCUIT BREAKER
2315741P18
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Function
reset
-
Circuit Protection Type
overcurrent all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.080 minimum at 300 pct all locations and 0.010 minimum at 400 pct all locations and 6.000 maximum at 200 pct all locations and 0.580 minimum at 200 pct all locations and 1.600 maximum at 300 pct all locations and 0.630 maximum at 400 pct all locations
-
Pole Quantity
2
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Reference Number Differentiating Characteristics
as differentiated by special test features
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Body Width
1.250 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Special Test Features
navord od36190
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc all locations
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Terminal Type And Quantity
4 wire hook
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Body Length
1.531 inches nominal
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Time Per Pole In Seconds
2.400 minimum all locations and 42.000 maximum all locations
-
Mounting Surface To Terminal End Distance
1.855 inches nominal
-
Thread Series Designator
unef
-
Bushing Length
0.340 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc all locations