2315741P13
Circuit Breakers
CIRCUIT BREAKER
2315741P13
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
1b multipole-single actuator type
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Ultimate Trip Time Per Pole In Seconds
2.400 minimum and 42.000 maximum all locations
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Nominal Thread Size
0.375 inches
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Special Test Features
navord od36190
-
Terminal Type And Quantity
4 wire hook
-
Bushing Length
0.340 inches nominal
-
Body Length
1.531 inches nominal
-
Body Width
1.250 inches nominal
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Mounting Surface To Terminal End Distance
1.855 inches nominal
-
Pole Quantity
2
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc all locations
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Characteristic
time delay all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
reset
-
Internal Trip Release Configuration
series trip all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.580 minimum at 200 pct and 6.000 maximum at 200 pct and 0.080 minimum at 300 pct and 1.600 maximum at 300 pct and 0.010 minimum at 400 pct and 0.630 maximum at 400 pct all locations
-
Design Control Reference
2315741p13
-
Manufacturers Code
10001
-
Thread Series Designator
unef
-
Reference Number Differentiating Characteristics
as differentiated by special test features