BS-2315741P17

Circuit Breakers

CIRCUIT BREAKER

BS-2315741P17

5925-00-866-2106

5925 - Circuit Breakers

British Sarozal Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Special Test Features

    navord od36190

  • Manufacturers Code

    10001

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Mounting Surface To Terminal End Distance

    1.855 inches nominal

  • Pole Quantity

    2

  • Terminal Type And Quantity

    4 wire hook

  • Reference Number Differentiating Characteristics

    as differentiated by special test features

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes dc all locations

  • Trip Release Method

    magnetic all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Design Control Reference

    2315741p17

  • Thread Series Designator

    unef

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.340 inches nominal

  • Body Length

    1.531 inches nominal

  • Body Width

    1.250 inches nominal

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Ultimate Trip Time Per Pole In Seconds

    2.400 minimum and 42.000 maximum all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    reset

  • Actuator Position Designation

    at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.580 minimum at 200 pct and 6.000 maximum at 200 pct and 0.080 minimum at 300 pct and 1.600 maximum at 300 pct and 0.010 minimum at 400 pct and 0.630 maximum at 400 pct all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...