807141-2
Circuit Breakers
CIRCUIT BREAKER
807141-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Inclosure Protection Type For Which Designed
vibrationproof and shockproof and hermetically sealed
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Thread Series Designator
unef
-
Body Width
0.640 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
1.5 amperes dc single location
-
Case Material
plastic
-
Body Length
1.500 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Pole Quantity
1
-
Bushing Length
0.625 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.090 minimum at 200 pct single location and 0.600 maximum at 200 pct single location
-
Terminal Type And Quantity
2 wire hook
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Mounting Facility Type And Quantity
1 threaded bushing