L4008A1015

Switches

SWITCH,THERMOSTATIC

L4008A1015

5930-00-866-5100

5930 - Switches

Honeywell Inc

SWITCH,THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Action Stimulus

    increase

  • Mounting Method

    base

  • Bulb Diameter

    0.375 inches nominal

  • Contact Load Current Rating

    5.0 amperes resistive load first voltage

  • Contact Voltage Rating In Volts

    12.0 dc at sea level third voltage

  • Overall Height

    5.625 inches nominal

  • Contact Adjustment Range

    +100.00/+240.00 actuation point degrees fahrenheit

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally closed, momentary action

  • Media For Which Designed

    gas or liquid

  • Contact Load Current Rating

    25.0 milliamperes resistive load third voltage

  • Contact Voltage Rating In Volts

    120.0 ac at sea level second voltage

  • Features Provided

    calibrated scale

  • Bulb Length

    3.125 inches nominal

  • Terminal Type

    tab w/screw

  • Contact Load Current Rating

    8.0 amperes resistive load second voltage

  • Capillary Tube Length

    60.000 inches nominal

  • Contact Adjustment Type

    external actuation point screw

  • Overall Width

    2.000 inches nominal

  • Contact Voltage Rating In Volts

    240.0 ac at sea level first voltage

  • Temp Sensing Element Type

    capillary tube-bulb

  • Contact Adjustability

    actuation point adjustable

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...