ETN1102

Circuit Breakers

CIRCUIT BREAKER

ETN1102

5925-00-866-8573

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.938 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.125 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    2.625 inches nominal

  • Case Material

    plastic

  • Body Height

    3.375 inches nominal

  • Body Length

    4.125 inches nominal

  • Boss Height

    0.125 inches nominal

  • Arc Quenching Method

    air

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    instantaneous and time delay

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 200.000 maximum at 200 pct

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal

  • Terminal Type And Quantity

    6 clip

  • Body Style

    multipole-single actuator type

  • Body Width

    3.343 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.216 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.625 inches nominal

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Trip Release Method

    thermal-magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    2.100 pounds

  • Precious Material And Location

    contacts silver

  • Precious Material

    silver

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...