F3050A

Circuit Breakers

CIRCUIT BREAKER

F3050A

5925-00-867-7337

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Trip Release Method

    thermal-magnetic

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal

  • Terminal Type And Quantity

    6 compression

  • Body Style

    multipole-single actuator type

  • Body Length

    9.365 inches minimum and 9.385 inches maximum

  • Boss Height

    0.178 inches minimum and 0.198 inches maximum

  • Pole Quantity

    3

  • Body Width

    4.115 inches minimum and 4.135 inches maximum

  • Body Height

    3.365 inches minimum and 3.385 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    7.240 inches minimum and 7.260 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.364 inches minimum and 1.384 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.790 inches minimum and 4.810 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.364 inches minimum and 1.384 inches maximum

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    instantaneous

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Frequency In Hertz

    60.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...