579R868H03
Circuit Breakers
CIRCUIT BREAKER
579R868H03
Northrop Grumman Systems Corporation
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches minimum and 0.770 inches maximum
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Body Length
2.500 inches minimum and 2.530 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.930 inches minimum and 1.950 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Main Contact Tripping Mechanism Type
trip free
-
External Actuator Linkage Arrangement
one, two, three, four, five, and six linked
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac first location
-
Terminal Type And Quantity
12 threaded stud
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Body Width
4.550 inches minimum and 4.570 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac sixth location
-
Frequency In Hertz
400.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac third location
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac fifth location
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Manual Actuator Type And Quantity
6 toggle
-
Mounting Facility Type And Quantity
12 threaded hole
-
Case Material
plastic
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
2.598 inches minimum and 2.742 inches maximum
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac fourth location
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Unpackaged Unit Weight
29.000 ounces
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Pole Quantity
6
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac second location
-
Inclosure Protection Type For Which Designed
general purpose