50671
Coils and Transformers
TRANSFORMER,POWER
50671
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Transformer Winding Connection Type
delta-wye
-
Body Length
5.062 inches nominal
-
Body Width
4.312 inches nominal
-
Maximum Operating Temp
75.0 deg celsius
-
Inclosure Type
hermetically sealed
-
Mounting Facility Quantity
4
-
Mounting Method
threaded stud
-
Nominal Thread Size
0.250 inches
-
Winding Operating Voltage
600.00 ac volts nominal
-
Thread Series Designator
unc
-
Terminal Type And Quantity
10 turret
-
Thread Class
2a
-
Center To Center Distance Between Mounting Facilities Parallel To Length
4.062 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
3.312 inches nominal
-
Winding Shielding Method
internal shield brought out to terminal
-
Body Height
6.812 inches nominal
-
Winding Function And Quantity
1 primary and 2 secondary
-
Thread Quantity Per Inch
20
-
Winding Operating Current
1.2 amperes ac maximum
-
Winding Operating Voltage
200.00 ac volts nominal
-
Winding Operating Voltage
203.00 ac volts nominal
-
Cognizant Service
usn
-
Thread Direction
right-hand
-
Reliability Indicator
not established
-
Frequency Rating
60.0 hertz nominal
-
Input-Output Phase Relationship
three phase to three phase