74-101-13

Circuit Breakers

CIRCUIT BREAKER

74-101-13

5925-00-871-3609

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.175 inches minimum and 1.205 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.180 inches minimum and 0.188 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.015 inches maximum

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations and 6.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations and 2000.0 dc

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Style

    2c multipole-multiple actuator type

  • Body Width

    2.235 inches minimum and 2.265 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 1.797 inches minimum and 1.827 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.765 inches maximum

  • Mounting Surface To Terminal End Distance

    1.985 inches minimum and 32

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 unthreaded hole

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations and 50.0 dc

  • Trip Release Method

    magnetic all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    shockproof

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    0.810 pounds

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...