3XAM1516HKMG3-1-416VAC400HZ2
Circuit Breakers
CIRCUIT BREAKER
3XAM1516HKMG3-1-416VAC400HZ2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Switch Terminal Type
tab, solder lug
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
-
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
-
Maximum Continuous Load Current Rating Per Pole
250.0 milliamperes ac second location
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Mounting Surface To Terminal End Distance
3.239 inches nominal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Center To Center Distance Between Terminals Parallel To Length
3.053 inches minimum and 3.073 inches maximum
-
Switch Current Rating And Type In Amps
5.0 ac and 5.0 dc
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Maximum Continuous Load Current Rating Per Pole
2000.0 milliamperes ac first location
-
Body Style
multipole-multiple actuator type
-
Body Length
3.709 inches minimum and 3.042 inches minimum and 3.062 inches maximum
-
Switch Voltage Rating And Type In Volts
115.0 ac and 28.0 dc
-
Switch Contact Arrangement
single pole, double throw
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Mounting Facility Type And Quantity
6 threaded hole
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Switch Location And Position Designation
external at pole three
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.021 inches minimum and moderately rugged
-
Frequency In Hertz
400.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac third location
-
Boss Height
0.146 inches minimum and 0.166 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Center To Center Distance Between Terminals Parallel To Width
1.021 inches minimum and 2.740 inches minimum and 2.760 inches maximum
-
Auxiliary Switch Function And Quantity
1 control
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
Special Handling Feature
magnetic
-
Pole Quantity
3