278A2184CKP3

Circuit Breakers

CIRCUIT BREAKER

278A2184CKP3

5925-00-876-9217

5925 - Circuit Breakers

General Electric Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-17361 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Body Length

    6.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.343 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Arc Quenching Method

    air

  • Center To Center Distance Between Terminals Parallel To Length

    3.938 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Boss Height

    0.187 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct all locations and 15.000 maximum at 200 pct all locations

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Specification/Standard Data

    81349-mil-c-17361/4 government specification

  • Special Features

    circuit breaker supplied with two threaded metal inserts

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.827 inches nominal

  • Case Material

    plastic

  • Body Height

    3.875 inches nominal

  • ~1

    data on certain environmental and performanc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Terminal Type And Quantity

    6 quick disconnect, male

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...