Technical Characteristics
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Operating Voltage Rating And Type Per Function
115.0 volts ac blank
-
Functional Terminal Type And Quantity
1 threaded stud output 2nd function
-
Average Life Rating In Hours
10000.0
-
Nominal Thread Size
0.138 inches
-
Maximum Dielectric Withstanding Dc Voltage
2.0 kilovolts at sea level
-
Mounting Facility Screw Thread Series Designator
unc
-
Inclosure Type
hermetically sealed
-
Overall Height
4.410 inches nominal
-
Mounting Facility Type And Quantity
4 threaded stud
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.687 inches nominal
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Input Impedance Per Function W/Load
50.0 ohms blank
-
Functional Terminal Type And Quantity
1 threaded stud input 1st function
-
Body Length
10.500 inches nominal
-
Body Width
3.250 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.875 inches nominal
-
Maximum Temp Rise
25.0 deg celsius
-
Principal Circuitry Type Per Function
inductance-capacitance blank
-
Overall Width
4.125 inches nominal
-
Body Surface Treatment
tin
-
Style Designator
rectangular terminal/terminals on adjacent surfaces
-
Body Material
metal
-
Overall Length
10.500 inches nominal
-
Unthreaded Mounting Hole Diameter
0.205 inches minimum and 0.215 inches maximum
-
Power Line Frequency Rating Per Function In Hertz
960.0 blank
-
Output Impedance Per Function W/Source Across Input
50.0 ohms blank
-
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
-
Operating Current Rating Per Function In Amps
3.0 blank
-
Vibration Resistance Range In Hertz
+10.0/+55.0