Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
~1
data on certain environmental and performance
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts teardrop, two holes type 4f single winding
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.421 inches nominal single mounting facility
-
Precious Material And Location
terminal surface gold
-
Precious Material
gold
-
Environmental Protection
hermetic
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Specification/Standard Data
96906-ms27400 government standard
-
Overall Height
1.280 inches nominal
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
-
Features Provided
polarized
-
Mounting Facility Pattern
triangle single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
-
Overall Width
1.025 inches maximum
-
Coil Quantity
1
-
Terminal Type And Quantity
14 pin all functions
-
Winding Dc Resistance Rating
290.0 ohms nominal single winding
-
Duty Type
continuous
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches nominal single mounting facility