SCA3200WSQCC

Circuit Breakers

CIRCUIT BREAKER

SCA3200WSQCC

5925-00-879-9567

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Body Length

    6.562 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Pole Quantity

    3

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.880 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    75.000 minimum at 200 pct all locations and 325.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Center To Center Distance Between Terminals Parallel To Length

    6.250 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Switch Current Rating And Type In Amps

    225.0 ac

  • Inclosure Protection Type For Which Designed

    general purpose

  • Boss Height

    0.219 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    200.0 amperes ac all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Height

    2.594 inches nominal

  • Switch Voltage Rating And Type In Volts

    240.0 ac

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...