210-506-9001

Circuit Breakers

CIRCUIT BREAKER

210-506-9001

5925-00-881-2463

5925 - Circuit Breakers

Honeywell International Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.750 inches maximum

  • ~1

    data on certain environmental and performance

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Inclosure Protection Type For Which Designed

    moisture resistant and explosion resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 65.000 maximum at 200 pct single location

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Thread Series Designator

    unc

  • Bushing Length

    0.250 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac single location and 60.0 amperes dc single location

  • Fragility Factor

    moderately rugged

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Circuit Protection Type

    overcurrent single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 6000.0 dc single location

  • Mounting Surface To Terminal End Distance

    2.250 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    2.189 inches maximum

  • Case Material

    metal

  • Pole Quantity

    1

  • Unpackaged Unit Weight

    5.000 ounces

  • Center To Center Distance Between Terminals Parallel To Length

    1.438 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Specification/Standard Data

    96906-ms25361 government standard

  • Trip Release Method

    thermal single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...