WFV3139

Filters and Networks

FILTER,BAND PASS

WFV3139

5915-00-881-5067

5915 - Filters and Networks

Cornell-Dubilier Electronics

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 2nd band pass and 40.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 30.0 minimum 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    4.0 1st band pass

  • Body Material

    metal

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Style Designator

    rectangular terminal/terminals on one surface

  • Operating Temp Range

    -55.0/+65.0 deg celsius

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.990 inches minimum and 4.010 inches maximum

  • Frequency Band Width Per Function

    1.10 kilohertz 2nd band pass and 1.90 kilohertz 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    4.5 2nd band pass

  • Input Impedance Per Function W/Load

    20.0 kilohms 1st band pass

  • Output Impedance Per Function W/Source Across Input

    2.0 kilohms 1st band pass

  • Functional Terminal Type And Quantity

    2 tab, solder lug input 1st function

  • Body Length

    4.750 inches maximum

  • Mounting Facility Screw Thread Series Designator

    unc

  • Nominal Thread Size

    0.164 inches

  • Input Impedance Per Function W/Load

    20.0 kilohms 2nd band pass

  • Output Impedance Per Function W/Source Across Input

    2.0 kilohms 2nd band pass

  • Body Height

    4.500 inches maximum

  • Overall Height

    5.000 inches maximum

  • Frequency Band Width Per Function

    500.00 hertz 1st band pass and 700.00 hertz 1st band pass

  • Functional Terminal Type And Quantity

    6 tab, solder lug output 2nd function

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 1st band pass and 40.0 minimum 1st band pass and 3.0 maximum 1st band pass and 40.0 minimum 1st band pass

  • Inclosure Type

    hermetically sealed

  • Body Width

    2.500 inches maximum

  • Reference Frequency Per Function

    1.5 single radio interference two phase to two phase

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.740 inches minimum and 1.760 inches maximum

  • Specified Frequencies Of Discrimination Per Function

    1.90 kilohertz 2nd band pass and 600.00 hertz 2nd band pass and 1.10 kilohertz 2nd band pass and 2.40 kilohertz 2nd band pass

  • Reference Frequency Per Function

    600.0 single high pass pulses per second

  • Specified Frequencies Of Discrimination Per Function

    300.00 hertz 1st band pass and 700.00 hertz 1st band pass and 500.00 hertz 1st band pass and 1.00 kilohertz 1st band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...