54B6820H05
Circuit Breakers
CIRCUIT BREAKER
54B6820H05
Northrop Grumman Systems Corporation
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Function
reset
-
Internal Trip Release Configuration
series trip
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Nominal Thread Size
0.138 inches
-
Case Material
plastic
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
6 threaded hole
-
Thread Quantity Per Inch
32
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Trip Delay Time In Seconds Per Rated Continuous Current
7.000 minimum at 150 pct and 60.000 maximum at 150 pct and 2.500 minimum at 200 pct and 8.000 maximum at 200 pct and 0.800 minimum at 300 pct and 2.200 maximum at 300 pct and 0.400 minimum at 400 pct and 1.200 maximum at 400 pct
-
Frequency In Hertz
400.0
-
Thread Series Designator
unc
-
Terminal Type And Quantity
6 threaded stud