374-203-101

Circuit Breakers

CIRCUIT BREAKER

374-203-101

5925-00-883-0090

5925 - Circuit Breakers

Wood Electric Operations Potter And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Thread Quantity Per Inch

    28

  • Case Material

    plastic

  • Bushing Length

    0.500 inches nominal

  • Thread Series Designator

    unef

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 45.000 maximum at 200 pct single location

  • Mounting Surface To Terminal End Distance

    1.815 inches nominal

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 2000.0 dc single location

  • Body Length

    1.375 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Arc Quenching Method

    air

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Nominal Thread Size

    0.438 inches

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Body Width

    0.660 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Unpackaged Unit Weight

    1.500 ounces

  • Center To Center Distance Between Terminals Parallel To Length

    0.850 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location and 3.0 amperes dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • End Item Identification

    nsn 4210-01-486-1035 tfft (tactical fire fighting truck)

  • Fragility Factor

    moderately rugged

  • Actuator Function

    reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...