10607304-5

Circuit Breakers

CIRCUIT BREAKER

10607304-5

5925-00-883-3843

5925 - Circuit Breakers

U S Army Aviation And Missile

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.860 inches minimum and 0.890 inches maximum

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Body Length

    2.631 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Center To Center Distance Between Terminals Parallel To Length

    1.422 inches minimum and 1.452 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.860 inches minimum and 0.890 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac all locations and 6000.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations and 100.0 amperes dc all locations

  • Thread Quantity Per Inch

    32

  • Arc Quenching Method

    air

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Body Width

    2.187 inches maximum

  • Inclosure Protection Type For Which Designed

    general purpose

  • Precious Material And Location

    contact surfaces silver

  • Unpackaged Unit Weight

    0.625 pounds

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct all locations and 55.000 maximum at 200 pct all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.138 inches

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-multiple actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.797 inches minimum and 1.827 inches maximum

  • Trip Release Method

    thermal all locations

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations and 30.0 dc all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Manual Actuator Type And Quantity

    3 push-pull

  • Frequency In Hertz

    400.0 all locations

  • Mounting Surface To Terminal End Distance

    2.422 inches minimum and 2.452 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...