376A603H01
Coils and Transformers
TRANSFORMER,POWER
376A603H01
Northrop Grumman Systems Corporation
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.620 inches nominal single mounting facility single center group
-
Mounting Slot Width
0.310 inches nominal single group
-
Frequency Rating
400.0 hertz nominal single component
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Body Length
2.880 inches maximum
-
Body Width
2.410 inches maximum
-
Body Height
2.690 inches maximum
-
Inclosure Type
open
-
Mounting Facility Quantity
4 single group
-
Mounting Method
flange and slot single group
-
Winding Function And Quantity
1 primary and 2 secondary single component
-
Winding Operating Current
10.0 amperes ac maximum single component 2nd secondary
-
Winding Operating Voltage
120.00 ac volts nominal single component single primary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.440 inches nominal single mounting facility single center group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Current
700.0 milliamperes ac maximum single component 1st secondary
-
Winding Operating Voltage
6.30 ac volts nominal single component all secondary
-
Terminal Type And Quantity
6 tab, solder lug