70-259-1

Circuit Breakers

CIRCUIT BREAKER

70-259-1

5925-00-884-0962

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 10.000 maximum at 200 pct single location

  • Iii Unpackaged Unit Weight

    0.312 pounds

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    general purpose

  • Frequency In Hertz

    400.0 single location

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.318 inches minimum and 2.462 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Actuator Position Designation

    at pole one

  • Body Style

    12a single pole type

  • Body Length

    2.500 inches minimum and 2.530 inches maximum

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.930 inches minimum and 1.950 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Pole Quantity

    1

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...