Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations and 2.0 amperes dc all locations

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Bushing Length

    0.400 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.688 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct all locations and 1.800 maximum at 200 pct all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    2.125 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Frequency In Hertz

    400.0 all locations

  • Body Height

    2.200 inches maximum

  • Body Width

    1.265 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac all locations and 28.0 dc all locations

  • Nominal Thread Size

    0.469 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Ultimate Trip Time Per Pole In Seconds

    3600.000 nominal all locations

  • Trip Release Method

    thermal all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...