5016669-20

Circuit Breakers

CIRCUIT BREAKER

5016669-20

5925-00-887-9380

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 24.0 dc single location

  • Thread Quantity Per Inch

    27

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Circuit Protection Type

    overcurrent single location

  • Nominal Thread Size

    0.375 inches

  • Manual Actuator Type And Quantity

    1 push button

  • Mounting Surface To Terminal End Distance

    2.240 inches minimum and 2.260 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Bushing Length

    0.381 inches minimum and 0.401 inches maximum

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    50.0 ac single location and 50.0 dc single location

  • Reset Method

    manual

  • Special Handling Feature

    magnetic

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Body Length

    1.803 inches minimum and 1.823 inches maximum

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Unpackaged Unit Weight

    0.062 pounds

  • Center To Center Distance Between Terminals Parallel To Length

    1.146 inches minimum and 1.168 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Body Width

    0.553 inches minimum and 0.573 inches maximum

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    waterproof and dustproof

  • Terminal Type And Quantity

    2 tab, solder lug

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...