S656D222G04

Circuit Breakers

CIRCUIT BREAKER

S656D222G04

5925-00-888-4242

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    6.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Boss Height

    0.156 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac and 30.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 250.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0

  • Nominal Thread Size

    0.138 inches

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Thread Series Designator

    unc

  • Body Style

    11b multipole-single actuator type

  • Body Width

    2.750 inches nominal

  • Body Height

    3.375 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.062 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    2 threaded hole and 3 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    7500.0 ac and 7500.0 dc all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    instantaneous and time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    27.000 minimum at 200 pct and 100.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    4 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...