6042H144

Relays and Solenoids

RELAY,ELECTROMAGNETIC

6042H144

5945-00-889-0962

5945 - Relays and Solenoids

Drs Power & Control Technologies

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Rating And Type At Specified Temp

    115.0 volts ac 25 deg celsius single winding

  • Environmental Protection

    hermetic

  • Auxiliary Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Arc Quenching Method

    air

  • Overall Width

    3.305 inches maximum

  • Winding Quantity

    1

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    2.887 inches nominal single mounting facility

  • Time Delay

    0.065 seconds maximum fixed release time

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    750.0 milliamperes ac lamp load and 750.0 milliamperes dc lamp load

  • Main Contact Load Current Rating At Maximum Rated Voltage

    25.0 amperes ac resistive load and 25.0 amperes dc resistive load

  • Overall Height

    4.576 inches maximum

  • Case Material

    metal

  • Test Data Document

    81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Nonpile-Up Main Contact Arrangement

    3 pole, single throw, normally open, double make, momentary action

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    3.250 inches nominal single mounting facility

  • Duty Type

    continuous

  • Main Contact Load Current Rating At Maximum Rated Voltage

    25.0 amperes ac inductive load and 25.0 amperes dc inductive load

  • Coil Quantity

    1

  • Cubic Measure

    55.597 cubic inches

  • Purpose For Which Designed

    general

  • Time Delay

    0.03 seconds maximum fixed operate time

  • Terminal Type And Quantity

    12 threaded stud all functions

  • Nonpile-Up Auxiliary Contact Arrangement

    1 pole, single throw, normally closed, double break, momentary action and 1 pole, single throw, normally open, double make, momentary action

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Unthreaded Mounting Hole Diameter

    0.218 inches nominal single mounting facility

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac inductive load and 5.0 amperes dc inductive load

  • ~1

    data on certain environmental and performance

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac resistive load and 5.0 amperes dc resistive load

  • Specification/Standard Data

    96906-ms24143 government standard

  • Overall Length

    3.700 inches maximum

  • Main Contact Load Current Rating At Maximum Rated Voltage

    25.0 amperes ac motor load and 25.0 amperes dc motor load

  • Frequency In Hertz

    60.0 nominal

  • Storage Type

    general purpose warehouse

  • Mounting Facility Pattern

    rectangular single mounting facility

  • Mounting Facility Type And Quantity

    4 unthreaded hole single mounting facility

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...