GC20C1-2
Circuit Breakers
CIRCUIT BREAKER
GC20C1-2
Northrop Grumman Systems Corporation
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac single location and 500.0 milliamperes dc single location
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Precious Material And Location
terminal surfaces silver
-
Terminal Type And Quantity
2 tab w/screw
-
Bushing Length
0.250 inches maximum
-
Body Width
0.750 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location and 5000.0 dc single location
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns
-
Case Material
plastic
-
Reset Actuator Voltage Rating And Type In Volts
120.0 ac and 30.0 dc
-
Fragility Factor
moderately rugged
-
Reset Method
electric
-
Actuator Function
trip w/separate reset
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Precious Material
silver
-
Storage Type
general purpose warehouse
-
Mounting Surface To Terminal End Distance
1.812 inches maximum
-
Body Length
1.137 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.400 minimum at 200 pct single location and 3.000 maximum at 200 pct single location
-
Thread Quantity Per Inch
32
-
Center To Center Distance Between Terminals Parallel To Length
0.650 inches nominal
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location and 28.0 dc single location
-
Inclosure Protection Type For Which Designed
explosion proof