40B6
Filters and Networks
FILTER,BAND PASS
40B6
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
14632-20810 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Functional Terminal Type And Quantity
1 pin ground 3rd function
-
Mounting Facility Type And Quantity
2 threaded stud
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.112 inches
-
Reference Frequency Per Function
2.0 megahertz blank
-
Input Impedance Per Function W/Load
1.0 kilohms blank
-
Specified Frequencies Of Discrimination Per Function
1.9999 megahertz blank and 1.9997 megahertz blank and 2.000 megahertz blank and 2.001 megahertz blank
-
Output Impedance Per Function W/Source Across Input
1.0 kilohms blank
-
Inclosure Type
hermetically sealed
-
Functional Terminal Type And Quantity
1 pin output 2nd function
-
Body Length
1.740 inches minimum and 1.760 inches maximum
-
Body Width
1.240 inches minimum and 1.260 inches maximum
-
Operating Temp Range
+0.0/+50.0 deg celsius
-
Insertion Loss At Reference Frequency Per Function In Decibels
6.0 blank
-
Frequency Band Width Per Function
1.999925 megahertz blank and 2.000075 megahertz blank
-
Discrimination At Specified Frequencies Per Function In Decibels
40.0 minimum blank and 3.0 maximum blank and 3.0 maximum blank and 40.0 minimum blank
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.240 inches minimum and 1.260 inches maximum
-
Body Height
1.050 inches minimum and 1.070 inches maximum
-
Overall Height
1.290 inches minimum and 1.330 inches maximum
-
Style Designator
rectangular terminal/terminals on one surface
-
Functional Terminal Type And Quantity
1 pin input 1st function