31761
Coils and Transformers
TRANSFORMER,POWER
31761
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
400.0 hertz nominal single component
-
Mounting Slot Width
0.170 inches nominal single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Test Data Document
97151-8810307 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Winding Operating Voltage
240.00 ac volts nominal single component 1st secondary
-
Overall Height
1.960 inches maximum
-
Mounting Method
flange single group and slot single group
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility single center group
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
40.00 ac volts nominal single component single primary
-
Overall Length
3.810 inches minimum and 4.000 inches maximum
-
Winding Operating Voltage
193.00 ac volts nominal single component 3rd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.090 inches minimum single mounting facility single center group and 3.290 inches maximum single mounting facility single center group
-
Winding Operating Voltage
254.00 ac volts nominal single component 2nd secondary
-
Winding Tap Location (Non-Core)
err-070
-
Inclosure Type
fully inclosed
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Terminal Type And Quantity
11 wire lead
-
Overall Width
2.870 inches minimum and 3.370 inches maximum
-
Reliability Indicator
not established