AA55571/02

Circuit Breakers

CIRCUIT BREAKER

AA55571/02

5925-00-894-8015

5925 - Circuit Breakers

Federal Commercial Item Description

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.566 inches minimum and 1.582 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.625 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.813 inches nominal

  • Nominal Thread Size

    0.164 inches

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 quick disconnect, female

  • Case Material

    plastic

  • Body Length

    2.000 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Body Height

    1.875 inches maximum

  • Inclosure Protection Type For Which Designed

    salt spray proof and vibration resistant and waterproof and shock resistant and fungus resistant

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...