AM1516MG3-50-250VAC60C3

Circuit Breakers

CIRCUIT BREAKER

AM1516MG3-50-250VAC60C3

5925-00-896-9626

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Body Length

    3.719 inches nominal

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Body Width

    0.990 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Pole Quantity

    1

  • Test Data Document

    06845-2055458 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.156 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Style

    single pole type

  • Unpackaged Unit Weight

    9.750 ounces

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Frequency In Hertz

    60.0 single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Fragility Factor

    moderately rugged

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and moisture resistant

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct single location and 0.900 maximum at 200 pct single location

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...