AM33DRK7-5-15-125-250VAC60C5
Circuit Breakers
CIRCUIT BREAKER
AM33DRK7-5-15-125-250VAC60C5
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
8c multipole-multiple actuator type
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Pole Quantity
2
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac first location
-
Circuit Protection Type
overcurrent all locations
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one and two linked
-
Internal Trip Release Configuration
series trip w/dual rating all locations
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 minimum at 150 pct and 2.800 maximum at 150 pct and 0.280 minimum at 200 p
-
Inclosure Protection Type For Which Designed
explosion resistant
-
Thread Series Designator
unc
-
Terminal Type And Quantity
6 threaded stud
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Body Width
1.490 inches minimum and 1.510 inches maximum
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Fragility Factor
moderately rugged
-
Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac second location
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac first location
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
2 toggle
-
~1
ct and 0.900 maximum at 200 pct and 0.100 minimum at 300 pct and 0.300 maximum a
-
~2
t 300 pct all locations
-
Frequency In Hertz
60.0