1500-051-5

Circuit Breakers

CIRCUIT BREAKER

1500-051-5

5925-00-899-2663

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Nominal Thread Size

    0.469 inches

  • Body Width

    0.750 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Mounting Surface To Terminal End Distance

    1.843 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 2500.0 dc single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Release Method

    thermal single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.669 inches minimum and 0.731 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct single location and 3.000 maximum at 200 pct single location

  • Unpackaged Unit Weight

    0.100 pounds

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Body Length

    1.187 inches maximum

  • Reset Method

    manual

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...