44003A
Resistors
RESISTOR,THERMAL
44003A
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Resistance Tolerance At A Specified Temp In Percent
-1.1/+1.1 5th resistance-temperature point
-
Zero Power Resistance At Specified Temp
2.691 kilohms 4th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-1.1/+1.1 8th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 4th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-10.5/+10.5 1st resistance-temperature point
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Inclosure Type
encapsulated
-
Thermal Time Constant In Seconds
10.0
-
Temp Points For Resistance Readings At Zero Power
-80.0 deg celsius 1st resistance-temperature point
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-1.0/+1.0
-
Terminal Length
3.000 inches nominal
-
Zero Power Resistance At Specified Temp
32.64 kilohms 2nd resistance-temperature point
-
Body Width
0.050 inches maximum
-
Resistance Tolerance At A Specified Temp In Percent
-1.0/+1.0 6th resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
1.0
-
Resistance Tolerance At A Specified Temp In Percent
-1.0/+1.0 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
120.0 deg celsius 9th resistance-temperature point
-
Zero Power Resistance At Specified Temp
310.9 ohms 7th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
150.0 deg celsius 10th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
40.0 deg celsius 6th resistance-temperature point
-
Maximum Operating Temp
150.0 deg celsius
-
Zero Power Resistance At Specified Temp
6.649 kilohms 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
20.0 deg celsius 5th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-3.4/+3.4 10th resistance-temperature point
-
Zero Power Resistance At Specified Temp
229.0 kilohms 1st resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-20.0 deg celsius 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
80.0 deg celsius 8th resistance-temperature point
-
Zero Power Resistance At Specified Temp
64.5 ohms 9th resistance-temperature point
-
Zero Power Resistance
1.000 kilohms
-
Terminal Diameter
0.008 inches nominal
-
Resistance Tolerance At A Specified Temp In Percent
-1.5/+1.5 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-50.0 deg celsius 2nd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
60.0 deg celsius 7th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-5.0/+5.0 2nd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-2.0/+2.0 3rd resistance-temperature point
-
Reference Temp In Deg Celsius
25.0
-
Body Outside Diameter
0.095 inches nominal
-
Style Designator
disk
-
Zero Power Resistance At Specified Temp
174.5 ohms 8th resistance-temperature point
-
Zero Power Resistance At Specified Temp
589.0 ohms 6th resistance-temperature point
-
Zero Power Resistance At Specified Temp
1.204 kilohms 5th resistance-temperature point
-
Cubic Measure
0.007 cubic inches
-
Terminal Surface Treatment
solder
-
Zero Power Resistance At Specified Temp
34.2 ohms 10th resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-1.8/+1.8 9th resistance-temperature point