ST86D19-1
Circuit Breakers
CIRCUIT BREAKER
ST86D19-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
2 threaded stud
-
Reset Method
automatic
-
Trip Release Characteristic
instantaneous single location
-
Mounting Facility Type And Quantity
2 terminal
-
Operating Voltage Type And Rating Per Pole In Volts
12.0 dc single location
-
Overall Height
0.790 inches maximum
-
Overall Width
1.810 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
End Item Identification
nsn 2320-01-097-0260 hemtt (heavy expanded mobility tactical trucks).
-
Internal Trip Release Configuration
series trip single location
-
Case Material
metal
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Overall Length
1.260 inches maximum
-
Trip Release Method
thermal single location
-
Circuit Protection Type
overcurrent single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc single location
-
Storage Type
general purpose warehouse
-
Body Style
rectangular dimensional envelope
-
Fragility Factor
moderately rugged